Connecting the mains supply cable
o The mains terminal block is located on the underside of the hob
and the terminals are accessible by removing the terminal block
cover by removing the cover screw.
o The cable connections must be in accordance with the diagram
located on the bottom of the hob.
o 1, 2 and 3 are the live connection, 4 and 5 are the neutral
connection and the remaining one is the earth connection.
o The live wire MUST be placed in connection number 1.
The neutral wire MUST be placed in connection number 4.
The earth wire MUST be placed in the connection marked with
the symbol.
o The brass links must be positioned as marked in the above
diagram and once established ALL terminal screws must be
tightened down firmly.
o Fit the cable and refit the cable clamp.
o If when the hob is first switched on, only two of the zones
work, you should recheck that the terminal screws are all
fully tightened between the links. This should be done
before contacting the Baumatic Service Department.
o IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the hob is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.